ZACTA Technology Corpration EMC RF Certification Product Safety Electrical Appliance & Materials (PSE) Reliability&Evaluation

JAPANESE

EMC/Produsts Safty service / Reliability & Evalution service

Company profile

Company Name
ZACTA Technology Corporation
Address
1-5-9 Nakagawa-Chuo, Tsuzuki-ku, Yokohama, Kanagawa, 224-0003 Japan
Established
October 1978
Capital
142million-yen
Representative
CEO&Chairman Yoshiharu Hatakeyama
President Fumiyuki Aikawa
Number of staffs
73 (SEP 2010)
Main Bank
Bank of Tokyo-Mitsubishi UFJ,  Mizuho Bank, Ltd.
Main services
・Reliability & Evaluation business : Usability evaluation
・EMC business : EMC testing, EMC solution, Agent for application
・Product Safety business : Agent for safety test and various product approval tie-up with the cooperated laboratory.

Milestones

1978 October
Established "Bangard Corporation" for the purpose of medical-device sales
1985 August
Changed company name to "Zacta Engineering Corporation"
1996 July
"Zacta Engineering Corporation" merged with "Zacta Technology Corporation" and changed the company name to "Zacta Technology Corporation"
1996 August
Anechoic chamber and immunity test facility were introduced, and started immunity testing service.
1997 February
Started Usability service.
1998 June
Accredited by NIST/NVLAP, USA.
1999 August
Accredited by ETL Semko.
2002 May
Started EMC testing service in Techno-Park Takatsu in Kawasaki area.
2002 June
Started Reliability service.
2002 May
Started EMC testing service in Techno-Park Takatsu in Kawasaki area.
2003 July
Yonezawa Testing Center and TP Takatsu Anechoic Chamber were authorized by TUV Rheinland.
2005 April
Started Usability / Reliability service at Yokohama area.
2005 June
Acquired ISO9001:2000 Certification (Yonezawa Testing Center).
2006 September
Started Product safety service.
2006 October
Acquired the Miyako Ajenda21 Forum of environmental management system Certification (Yonezawa Testing Center).
2006 December
Introduced 3m & 10m Anechoic Chamber in Yonezawa Testing Center and started service.
2007 January
Started service of the domestic radio law.
2007 March
Accredited by BV, France.
2008 March
Started In-vehicle equipment EMC testing service.
2008 November
Accredited by VCA, Britain.
2009 January
Registered as “Registered Certification Body” under the Japanese Radio Law, Started services.
2009 March
Permitted by Ministry of Health,Labour and Welfare(MHLW), started detached service.
2010 September
Accreditated as an EMC laboratory by Taiwan BSMI..

Location

Main Office
1-5-9 Nakagawa-chuo, Tsuzuki-ku, Yokohama, Kanagawa, 224-0003 Japan
TEL 045-910-0880(From outside Japan(+81)45-910-0880)
FAX 045-910-0881(From outside Japan(+81)45-910-0881)
Yonezawa Testing Center
4149-7, 5-Chome, Hachimanpara, Yonezawa, Yamagata, 992-1128 Japan
TEL 0238-28-2880(From outside Japan(+81)238-28-2880)
FAX 0238-28-2888(From outside Japan(+81)238-28-2888)
Techno Park TAKATSU
2-6-1 Kitamikata, Takatsu-ku, Kawasaki, Kanagawa, 213-0005 Japan

Related Organizations

  • VCCI(VCCI Council)  
  • FCC(Federal Communication Commision)
  • NVLAP(National Voluntary Accrediation Program)  
  • Intertek ETL SEMKO(Certification Body)
  • TUV Rheinland(Certification Body)  
  • ISO9001:2000  
  • Kansai Electronic Industry Development Center  
  • BV(Bureau Veritas.)
  • VLAC(Voluntary EMC Laboratory Accreditaion Center Inc.)

PAGETOP

RF Certification Service

Radio services menu for JAPAN

Registered certification Body:011

RF Certification Service ZACTA was registered as “Registered Certification Body” under the Japanese Radio Law by the Minister of Internal Affairs and Communications. With this registration, we started our services for testing and certification of radio equipment, such as wireless LAN or bluetooth.

certification of conformity with technical regulations

  • No-lincense required:17categories
  • Blanket license :31 categories
  • Others:75 categories

RF Certification Service

Testing for high frequency equipment,issue notification

  • RFID,Carrier Interphone, PLC, microwave…

PAGETOP

EMC

Testing Center Recognized Internationally

ZACTA technology is accredited by VLAC, NVLAP, and recognized by BV and Intertek ETL semko, and TUV Rheinland that is international recognized based on International Standard (ISO/IEC17025) for the quality.

Reliable EMC solution service

We have been providing EMC solution services to a wide variety of devices for 15 years, and our technical skill is highly regarded by our clients.

EMC Testing

  • Our experienced engineers are capable to perform testing services in accordance with the specific country standard of your needs.
  • There are two kinds of test services, witness test and consignment test.

EMC

EMC Solution & Consulting

  • Our experienced engineers offer the most efficient and effective solustions for your product to satisfy the requirements of each standard.
  • We also offer the consulting service from the designstage.
  • Consulting service is availble both at Zacta facility or on your site.

EMC

On site EMC Testig

  • For a large-scale industrial equipment, we can offer our on-site service that can be performed at your facility for both EMC testing and solutions.
  • We also offer the enviromental measuring service for electromagnetic interferences.

Application agency service

  • It is service that executes FCC Certification and the CB Certification as a proxy.

Collaboration Service

  • We can be the point of contact on your behalf for coordinating the safety test, and to obtaining product approvals from CCC(China), BSMI (Taiwan) and other agencies.

Other Services

  • Calibration Service
  • Site Attenuation Measurement
  • Field Uniformity Test
  • Investigation of Standard
  • Antenna pattern Test

PAGETOP

Product Safety Service

Electrical Appliances and Materials Safety Law(JAPAN)

Testing for Electrical Appliances and Materials

EMCExceptions apply to Specified Electrical Appliances and Materials

Electrical Appliances and Materials Safety Law

  • Ministerial Ordinance for Determining Technical Standards for Electrical Appliances
  • Paragraph 1 Standards Attached Table 8
  • Paragraph 2 Standards (J-IEC standard:J60950,J60335,J60065 / Noise Intensity:J55001,J55014,J55022)

PAGETOP

Reliability&Evaluation

Verification Test

  • Basic functional operation verification
  • Application Software operation verification (single/composite)
  • LAN(cable/wireless)/Communication test/Field test
  • Hardware compatibility test (option/multi-vendor test)
  • Stability test(stress test/running test)
  • Abnormal/Illegal operation test
  • User manual(user document) check test
  • Environmental test / Reliability test

Reliability&Evaluation

Reliability Test

  • Temp./Humidity test
  • Heat impact test
  • Drop test
  • Vibration test
  • ESD test
  • Short Circuit test

PAGETOP

Facilities

YONEZAWA Testing Center
Facility Spec.
Open-site (#2 & #3) Shield room inside dimensions 12m L × 8m W × 6m H
Maxi. power supply ability 6kVA
Attenuation characteristic ±4dB
Measurement distance 3m , 10m
Turntable Diameter 2.6m / Load capacity 1.0t
Power supply for EUT Single-phase AC100V - 240V/2kVA
Shield room 1 Shield room inside dimensions 7m L× 4m W × 3m H
Maxi. power supply ability Single / three-phase AC20V - 480V/50kVA
Product entrance dimention 2m W × 2m H
Shield room 2 Shield room inside dimensions 4m L× 10m W × 2.4m H
Power supply for EUT 6kVA
Product entrance dimention 2m W × 2m H
10m Anechoic Chamber (EMI/EMS) Shield room inside dimensions 21m L × 13.5m W × 8.5m H
Power supply Single / three-phase AC20V - 480V/50kVA
Attenuation characteristic ±3dB
Measurement distance 3m , 10m
Turntable Diameter 3.0m / Load capacity 1.0t
Product entrance dimention 2m W × 2m H
3m Anechoic Chamber (EMI) Shield room inside dimensions 9m L × 6m W × 6m H
Power supply Single / three-phase AC20V - 480V/50kVA
Attenuation characteristic ±4dB
Measurement distance 1m , 3m
Turntable Diameter 1.5m / Load capacity 0.5t
Product entrance dimention 1.5m W × 2m H
Anechoic Chamber (EMI) Shield room inside dimensions 7.2m L × 3.8m W × 3.8m H
Maxi. power supply ability 2kVA
Turntable Diameter 1.2m / Load capacity 0.3t
Product entrance dimention 2m W × 1.8m H
Anechoic Chamber (RS) Shield room inside dimensions 7.0m L × 4.0m W × 3.0m H
Power supply Single / three-phase AC20V - 480V/50kVA
Turntable Diameter 1.5m / Load capacity 0.3t
Product entrance dimention 1.5m W × 2.0m H
Techno park TAKATSU
Facility Spec.
3m Anechoic Chamber Shield room inside dimensions 8.5m L × 5.5m W × 5.25m H
Power supply Single-phase 2kVA
Attenuation characteristic ±4dB
Turntable Diameter 2.0m / Load capacity 0.5t
Product entrance dimention 1m W × 2m H
Shield room Shield room inside dimensions 6.0m L × 4.0m W × 3.1m H
Power supply Single-phase 2kVA
Product entrance dimention 1m W × 2m H

PAGETOP