Company profile
- Company Name
- ZACTA Technology Corporation
- Address
- 1-5-9 Nakagawa-Chuo, Tsuzuki-ku, Yokohama, Kanagawa, 224-0003 Japan
- Established
- October 1978
- Capital
- 142million-yen
- Representative
- CEO&Chairman Yoshiharu Hatakeyama
President Fumiyuki Aikawa - Number of staffs
- 73 (SEP 2010)
- Main Bank
- Bank of Tokyo-Mitsubishi UFJ, Mizuho Bank, Ltd.
- Main services
- ・Reliability & Evaluation business : Usability evaluation
・EMC business : EMC testing, EMC solution, Agent for application
・Product Safety business : Agent for safety test and various product approval tie-up with the cooperated laboratory.
Milestones
- 1978 October
- Established "Bangard Corporation" for the purpose of medical-device sales
- 1985 August
- Changed company name to "Zacta Engineering Corporation"
- 1996 July
- "Zacta Engineering Corporation" merged with "Zacta Technology Corporation" and changed the company name to "Zacta Technology Corporation"
- 1996 August
- Anechoic chamber and immunity test facility were introduced, and started immunity testing service.
- 1997 February
- Started Usability service.
- 1998 June
- Accredited by NIST/NVLAP, USA.
- 1999 August
- Accredited by ETL Semko.
- 2002 May
- Started EMC testing service in Techno-Park Takatsu in Kawasaki area.
- 2002 June
- Started Reliability service.
- 2002 May
- Started EMC testing service in Techno-Park Takatsu in Kawasaki area.
- 2003 July
- Yonezawa Testing Center and TP Takatsu Anechoic Chamber were authorized by TUV Rheinland.
- 2005 April
- Started Usability / Reliability service at Yokohama area.
- 2005 June
- Acquired ISO9001:2000 Certification (Yonezawa Testing Center).
- 2006 September
- Started Product safety service.
- 2006 October
- Acquired the Miyako Ajenda21 Forum of environmental management system Certification (Yonezawa Testing Center).
- 2006 December
- Introduced 3m & 10m Anechoic Chamber in Yonezawa Testing Center and started service.
- 2007 January
- Started service of the domestic radio law.
- 2007 March
- Accredited by BV, France.
- 2008 March
- Started In-vehicle equipment EMC testing service.
- 2008 November
- Accredited by VCA, Britain.
- 2009 January
- Registered as “Registered Certification Body” under the Japanese Radio Law, Started services.
- 2009 March
- Permitted by Ministry of Health,Labour and Welfare(MHLW), started detached service.
- 2010 September
- Accreditated as an EMC laboratory by Taiwan BSMI..
Location
- Main Office
- 1-5-9 Nakagawa-chuo, Tsuzuki-ku, Yokohama, Kanagawa, 224-0003 Japan
TEL 045-910-0880(From outside Japan(+81)45-910-0880)
FAX 045-910-0881(From outside Japan(+81)45-910-0881) - Yonezawa Testing Center
- 4149-7, 5-Chome, Hachimanpara, Yonezawa, Yamagata, 992-1128 Japan
TEL 0238-28-2880(From outside Japan(+81)238-28-2880)
FAX 0238-28-2888(From outside Japan(+81)238-28-2888) - Techno Park TAKATSU
- 2-6-1 Kitamikata, Takatsu-ku, Kawasaki, Kanagawa, 213-0005 Japan
Related Organizations
- VCCI(VCCI Council)
- FCC(Federal Communication Commision)
- NVLAP(National Voluntary Accrediation Program)
- Intertek ETL SEMKO(Certification Body)
- TUV Rheinland(Certification Body)
- ISO9001:2000
- Kansai Electronic Industry Development Center
- BV(Bureau Veritas.)
- VLAC(Voluntary EMC Laboratory Accreditaion Center Inc.)
RF Certification Service
Radio services menu for JAPAN
Registered certification Body:011
ZACTA was registered as “Registered Certification Body” under the Japanese Radio Law by the Minister of Internal Affairs and Communications. With this registration, we started our services for testing and certification of radio equipment, such as wireless LAN or bluetooth.
certification of conformity with technical regulations
- No-lincense required:17categories
- Blanket license :31 categories
- Others:75 categories

Testing for high frequency equipment,issue notification
- RFID,Carrier Interphone, PLC, microwave…
EMC
Testing Center Recognized Internationally
ZACTA technology is accredited by VLAC, NVLAP, and recognized by BV and Intertek ETL semko, and TUV Rheinland that is international recognized based on International Standard (ISO/IEC17025) for the quality.
Reliable EMC solution service
We have been providing EMC solution services to a wide variety of devices for 15 years, and our technical skill is highly regarded by our clients.
EMC Testing
- Our experienced engineers are capable to perform testing services in accordance with the specific country standard of your needs.
- There are two kinds of test services, witness test and consignment test.

EMC Solution & Consulting
- Our experienced engineers offer the most efficient and effective solustions for your product to satisfy the requirements of each standard.
- We also offer the consulting service from the designstage.
- Consulting service is availble both at Zacta facility or on your site.

On site EMC Testig
- For a large-scale industrial equipment, we can offer our on-site service that can be performed at your facility for both EMC testing and solutions.
- We also offer the enviromental measuring service for electromagnetic interferences.
Application agency service
- It is service that executes FCC Certification and the CB Certification as a proxy.
Collaboration Service
- We can be the point of contact on your behalf for coordinating the safety test, and to obtaining product approvals from CCC(China), BSMI (Taiwan) and other agencies.
Other Services
- Calibration Service
- Site Attenuation Measurement
- Field Uniformity Test
- Investigation of Standard
- Antenna pattern Test
Product Safety Service
Electrical Appliances and Materials Safety Law(JAPAN)
Testing for Electrical Appliances and Materials
Exceptions apply to Specified Electrical Appliances and Materials
Electrical Appliances and Materials Safety Law
- Ministerial Ordinance for Determining Technical Standards for Electrical Appliances
- Paragraph 1 Standards Attached Table 8
- Paragraph 2 Standards (J-IEC standard:J60950,J60335,J60065 / Noise Intensity:J55001,J55014,J55022)
Reliability&Evaluation
Verification Test
- Basic functional operation verification
- Application Software operation verification (single/composite)
- LAN(cable/wireless)/Communication test/Field test
- Hardware compatibility test (option/multi-vendor test)
- Stability test(stress test/running test)
- Abnormal/Illegal operation test
- User manual(user document) check test
- Environmental test / Reliability test

Reliability Test
- Temp./Humidity test
- Heat impact test
- Drop test
- Vibration test
- ESD test
- Short Circuit test
Facilities
| YONEZAWA Testing Center | ||
|---|---|---|
| Facility | Spec. | |
| Open-site (#2 & #3) | Shield room inside dimensions | 12m L × 8m W × 6m H |
| Maxi. power supply ability | 6kVA | |
| Attenuation characteristic | ±4dB | |
| Measurement distance | 3m , 10m | |
| Turntable | Diameter 2.6m / Load capacity 1.0t | |
| Power supply for EUT | Single-phase AC100V - 240V/2kVA | |
| Shield room 1 | Shield room inside dimensions | 7m L× 4m W × 3m H |
| Maxi. power supply ability | Single / three-phase AC20V - 480V/50kVA | |
| Product entrance dimention | 2m W × 2m H | |
| Shield room 2 | Shield room inside dimensions | 4m L× 10m W × 2.4m H |
| Power supply for EUT | 6kVA | |
| Product entrance dimention | 2m W × 2m H | |
| 10m Anechoic Chamber (EMI/EMS) | Shield room inside dimensions | 21m L × 13.5m W × 8.5m H |
| Power supply | Single / three-phase AC20V - 480V/50kVA | |
| Attenuation characteristic | ±3dB | |
| Measurement distance | 3m , 10m | |
| Turntable | Diameter 3.0m / Load capacity 1.0t | |
| Product entrance dimention | 2m W × 2m H | |
| 3m Anechoic Chamber (EMI) | Shield room inside dimensions | 9m L × 6m W × 6m H |
| Power supply | Single / three-phase AC20V - 480V/50kVA | |
| Attenuation characteristic | ±4dB | |
| Measurement distance | 1m , 3m | |
| Turntable | Diameter 1.5m / Load capacity 0.5t | |
| Product entrance dimention | 1.5m W × 2m H | |
| Anechoic Chamber (EMI) | Shield room inside dimensions | 7.2m L × 3.8m W × 3.8m H |
| Maxi. power supply ability | 2kVA | |
| Turntable | Diameter 1.2m / Load capacity 0.3t | |
| Product entrance dimention | 2m W × 1.8m H | |
| Anechoic Chamber (RS) | Shield room inside dimensions | 7.0m L × 4.0m W × 3.0m H |
| Power supply | Single / three-phase AC20V - 480V/50kVA | |
| Turntable | Diameter 1.5m / Load capacity 0.3t | |
| Product entrance dimention | 1.5m W × 2.0m H | |
| Techno park TAKATSU | ||
| Facility | Spec. | |
| 3m Anechoic Chamber | Shield room inside dimensions | 8.5m L × 5.5m W × 5.25m H |
| Power supply | Single-phase 2kVA | |
| Attenuation characteristic | ±4dB | |
| Turntable | Diameter 2.0m / Load capacity 0.5t | |
| Product entrance dimention | 1m W × 2m H | |
| Shield room | Shield room inside dimensions | 6.0m L × 4.0m W × 3.1m H |
| Power supply | Single-phase 2kVA | |
| Product entrance dimention | 1m W × 2m H | |